Manifacturer | ENDA |
Ambient/Storage Temperature | 0…50 ºC / -25…70 ºC |
Relative Humidity | 80% relative humidity for temperatures up to 31 °C, decreasing linearly to 50% at 40 °C |
Protection Degree | According to EN 60529 Front panel: IP65, Rear panel: IP20 |
Height | Max. 2000m |
Supply | 90-250V AC, 50/60Hz |
Power Consumption | 7VA |
External Connections | Plug-in terminals |
Scale | Pt-100 resistance thermometer -200.0…850.0 °C / -100.0…160.0 °C |
Pt30Rh-Pt6Rh (B) thermocouple 200.0…1800.0 °C | |
NiCr-Con (E) thermocouple -100.0…900.0 °C | |
Fe-Con (J) thermocouple -100.0…900.0 °C | |
NiCr-Ni (K) thermocouple -100.0…1300.0 °C | |
Fe-Con (L) thermocouple -100.0…900.0 °C | |
NiCrSi-NiSi (N) thermocouple -200.0…1300.0 °C | |
Pt13Rh-Pt (R) thermocouple 0.0…1700.0 °C | |
Pt10Rh-Pt (S) thermocouple 0.0…1700.0 °C | |
Cu-Con (T) thermocouple -250.0…300.0 °C | |
Cu-Con (U) thermocouple -200.0…400.0 °C | |
NTC -60.0…150.0 °C | |
For 0/4 – 20mA, 0 – 150mV, 0/1 – 5V, 0 – 10V, 0 – 550ohm, 0 – 10kohm: | |
-32768…32767 (decimal point can be adjusted between 1. and 3. digits) | |
Digital Input | 5V or 30V pulse , Ri=100kohm (in order to use for profile control process) |
Accuracy | ±%0.1 or ±2 °C (for B type thermocouple) |
±%0.1 or ±0.5 °C (for E, J, K, N, T, U type thermocouple, Pt-100 resistance thermometer, NTC probe) | |
±%0.1 or ±1.5 °C (for L type thermocouple) | |
±%0.1 or ±1 °C (for R, S type thermocouple) | |
±%0.1 or ±1 digit (for 0/4 – 20mA, 0/1 – 5V, 0 – 10V) | |
±%0.1 or ±20μV (for 0 – 150mV) | |
±%0.2 or ±0.1ohm (for 0 – 550ohm) | |
±%0.5 or ±10ohm (for 0 – 10kohm) | |
Line Resistance | For Thermocouple, Pt-100, NTC, mV, V, ohm Ri > 100kohm |
For mA Ri = 50ohm | |
Control/Alarm 3 Output | Relay: 250V AC, 2A (resistive load), NO+NC |
Alarm 1 Output | Relay: 250V AC, 2A ( resistive load), NO+NC |
Alarm 2 Output | Relay: 250V AC, 2A ( resistive load), NO |
SSR Output | Max. 40mA, 0 – 12V, short-circuit protection |
mA Output | 0 – 20mA or 4 – 20mA max. load resistance is 750ohm |
V Output | Max. 30mA, 0 – 10V DC, short-circuit protection |
Life Expectancy | Mechanical 10.000.000 operations (under no load), Electrical 200.000 operations (2A at 250V AC, resistive load) |
Mounting Method | Panel mounting |
Dimensions | W96xH96xD81 mm |
Weight | Approx. 400g (after packaging) |
Enclosure Material | Self extinguishing plastics |
Enda, Temperature & Process Controllers, Temperature & Process Controllers
EPC9513
- 3,5 inches TFT , graphic and 5 digit display
- Selectable TC, RTD, NTC, R, mA, V or mV inputs
- Input offset feature
- 32 point linearization for analog inputs
- Selectable relay, SSR or analog outputs
- Selectable, input proportional transmitter output (mA or V)
- 50ms sampling time
- PID control
- PID selftune
- PID auto-tune
- Soft-Start feature
- 24Vdc for sensor supply
- 16 program and 8 step for profile control
- Selectable Single Setpoint Mode or Profile Control Mode
- Digital inputs for profile control
- In case of sensor failure manually, periodical or auto-periodical control can be selected
- Security levels for menu and configuration pages
- RS-485 ModBus protocol communication feature (optional)
- CE marked according to Europen Norms