Login to see prices
Enda

Ambient/Storage Temperature 0…50 ºC / -25…70 ºC
Relative Humidity 80% relative humidity for temperatures up to 31°C, decreasing linearly to 50% at 40°C
Protection Degree According to EN 60529 Front panel:IP65 Rear panel:IP20
Height Max. 2000m

917,00

  • Control panel for cold rooms with single-phase compressor up to 2HP
  • On-Off control
  • Six relay outputs for cooling,defrost,fan,lighting,alarm and aux relay
  • Three NTC probe inputs for cooling, defrost and optional display control
  • Programmable two digital input
  • Offset value can be entered for NTC probe
  • Compressor protection parameters can be entered
  • In the case of probe failure, output state can be selected as on-off or periodical running
  • Selectable “Smart Defrost” feature
  • Manual fast cooling feature
  • Upper and lower limits of the setpoint can be adjusted
  • Defrosting duration and interval can be adjusted
  • Upper and lower limits of the alarm value can be adjusted depending on the setpoint value
  • Temperature unit can be selected as °C or °F
  • Parameter can be transferred by using “ENDAKEY” without connecting the device to mains supply
  • Communication feature over RS485 ModBus protocol (optional)
  • CE marked according to European Norms